Hortitek Light Management Unit (LMU) - 6 Outlet | 7200W | 40A | 1 Phase

SKU: CTRL10101
|

ETA: 1-3 Weeks

Product main image

FREE SHIPPING OVER $499*

REG. PRICE: $390.00
$299.95
Qty:

Pick up at store Free

Delivery Options:

If cart total is less than $499*

Freight applies

If cart total is $499* & above

Free

*excluding bulky items

International shipping

Click here

SECURE PAYMENTS WITH

BUY NOW, PAY LATER

Pay in 4, interest-free. Afterpay it.

ZIP NOW, PAY LATER

Repay on a convenient weekly, fortnightly or monthly schedule.

ENJOY NOW, PAY LATER

Hortitek Light Management Units (LMU) are a safe and efficient way to manage your lighting system. They are hard-wired and need to be installed by a qualified electrician. The LMUs come in a range of sizes to suit your specific needs. They are all made with quality components and will give you many years of reliable service if used correctly.

Recommendation:

  • 315/400W Lamp - Max Qty: 20
  • 600/630W Lamp - Max Qty: 16
  • 800W Lamp - Max Qty: 12
  • 1000W Lamp - Max Qty: 6

Specifications

  • Phase: 1
  • Max Amps: 40
  • Continuous Amps: 32
  • Note: This LMU can supply up to 32 A load for 24 hrs operation
  • Voltage: 240 VAC
  • Frequency: 50 Hz

In The Box

  • [1] x Hortitek Light Management Unit (LMU) - 6 Outlet | 7200W | 40A | 1 Phase

Installation Instructions:

  1. All electrical items must be installed by a licensed electrical contractor.
  2. Check LMU Voltage and Wattage Rating before connecting to any supply.
  3. Loosen screws for each of the joiners. Connect the Neutral (Black wire) from the LMU to the supply Neutral and RED wires to Active Ensure that no bare copper wire protrudes from outside of the joiner. If so, shorten the stripped wire prior to tightening.
  4. Ensure that the joiner is generously taped and that wires are double insulated with tape and each wire is individually taped away from each other.
  5. Connect the supply earth (green and yellow wire) to earth terminal provided on the top of the LMU.
  6. Prior to commissioning, plug in the auxiliary lead (grey lead) into a 10 Amp socket and test the LMU.
  7. Set 24 Hrs Timer to desired ON/OFF time before switching Auxiliary supply.
  8. Read all the warnings on LMU before commissioning.

1-Year Replacement Warranty

  • If the product is faulty within the warranty period, the product will be replaced with a new one.
  • Please send the product to the following address on the contact us page.